DS Fully Automatic Chemistry Analyzer
  • Technical Specification

Model

DS401

DS301

DS261

DS161

Assay Model

Random access with direct reading system

Method

End point, Kinetic, Fixed time, Immunoturbidimetry,1-2 reagent,
Multista ndard, reagent/serum blank,etc

Assay Item

80assay

40assay

36assay

ISE mould (Na K Cl / Li) available on request

Throughput

1 Reagent

400 tests/h

300tests/h(max)

240tests/h(max)

200 tests/h(max)

2 Reagent

400 tests/h

240 tests/h

150 tests/h

150 tests/h max

With ISE

+120tests/h

+120 tests/h

+120 tests/h

+100 tests/h

Test Menu

T.BlLl     r-GT/GGT     CHO     Ca     APOB-l/B     CHE

D.BILI    ALPIAKP       TG      CL     APOB        CREA

TP       UREA         CK       P     CK-MB       Mg

ALB      CREA         LDH      C     ASO         AFU

Lactic Acid  ALTIGPT     UA      ɑ-HBDH  CO2        FMN

LP(a)      AST/GOT    GLU      AMY    LDL-C       HDL-C

CHE       LA         TBA      ADA    HS-CRP       PA

Fe        Cu          Zn       C3      C4          IgG

IgM       lgA            and drug, toxicity, etc…

Sample Position

80

60

60

50

Including standard, control and stat; either serum cup or primary
tube available

Sample Volume

1~100μl, 0.1μl I step

Reagent Position

2*40

40 or 80(optional)

36

Reagent Volume

R1 :1~400μl , 1μl/step, R2:1~400 μl, 1μl/step

Reagent/Sample Probe

With liquid level sensor, collision sensor, teflon coating and automatic
washing station

Reaction Time

0~999 seconds

Cuvette

High quality uv-transmitted plastic cuvette. Quartz glass cuvettes
available on request

Cuvette Washing

8 channels automatic washing system for reaction cuvettes

5channels

Probe And Mixer Washing

Independent washing station for each sample/reagent probe and mixer

Alarm

Automatic alarm for malfunction (eg: collision, reagent I sample insufficiency, full waste container, etc)

Calibration

Linear, Non-linear, Multi standard, K factor

Dilution/Retest sample

Sample can be diluted and retested if results are out of range or Sample is insufficient. Also with calibrator auto diluting function

Wavelength

340~810nm

Light Source

Halogen lamp

Absorbance Resolution

0.001A

Absorbance Accuracy

±0.0003A(0-2.5A)

Repeatability (CV %)

≤2%

Quality Control

Levy Jennings quality control program at 3 levels

Bar Code

Optional

Printer

Multiple report formats available

Test Control Function

New card control 3 stem available on request

Language

English, French, Spanish, German, Russian, etc.

System

Windows XP or Vista ; Windows 7

Power Supply

220V / 50Hz or 110V / 60Hz (optional)

Dimension

100*85*70cm

85*72*53cm

85*72*53cm

65*53*52cm

Wight

137Kg

90Kg

85Kg

45Kg

Product Catalog