Model |
DS401 |
DS301 |
DS261 |
DS161 |
|
Assay Model |
Random access with direct reading system |
||||
Method |
End point, Kinetic, Fixed time, Immunoturbidimetry,1-2 reagent, |
||||
Assay Item |
80assay |
40assay |
36assay |
||
ISE mould (Na K Cl / Li) available on request |
|||||
Throughput |
1 Reagent |
400 tests/h |
300tests/h(max) |
240tests/h(max) |
200 tests/h(max) |
2 Reagent |
400 tests/h |
240 tests/h |
150 tests/h |
150 tests/h max |
|
With ISE |
+120tests/h |
+120 tests/h |
+120 tests/h |
+100 tests/h |
|
Test Menu |
T.BlLl r-GT/GGT CHO Ca APOB-l/B CHE |
||||
D.BILI ALPIAKP TG CL APOB CREA |
|||||
TP UREA CK P CK-MB Mg |
|||||
ALB CREA LDH C ASO AFU |
|||||
Lactic Acid ALTIGPT UA ɑ-HBDH CO2 FMN |
|||||
LP(a) AST/GOT GLU AMY LDL-C HDL-C |
|||||
CHE LA TBA ADA HS-CRP PA |
|||||
Fe Cu Zn C3 C4 IgG |
|||||
IgM lgA and drug, toxicity, etc… |
|||||
Sample Position |
80 |
60 |
60 |
50 |
|
Including standard, control and stat; either serum cup or primary |
|||||
Sample Volume |
1~100μl, 0.1μl I step |
||||
Reagent Position |
2*40 |
40 or 80(optional) |
36 |
||
Reagent Volume |
R1 :1~400μl , 1μl/step, R2:1~400 μl, 1μl/step |
||||
Reagent/Sample Probe |
With liquid level sensor, collision sensor, teflon coating and automatic |
||||
Reaction Time |
0~999 seconds |
||||
Cuvette |
High quality uv-transmitted plastic cuvette. Quartz glass cuvettes |
||||
Cuvette Washing |
8 channels automatic washing system for reaction cuvettes |
5channels |
|||
Probe And Mixer Washing |
Independent washing station for each sample/reagent probe and mixer |
||||
Alarm |
Automatic alarm for malfunction (eg: collision, reagent I sample insufficiency, full waste container, etc) |
||||
Calibration |
Linear, Non-linear, Multi standard, K factor |
||||
Dilution/Retest sample |
Sample can be diluted and retested if results are out of range or Sample is insufficient. Also with calibrator auto diluting function |
||||
Wavelength |
340~810nm |
||||
Light Source |
Halogen lamp |
||||
Absorbance Resolution |
0.001A |
||||
Absorbance Accuracy |
±0.0003A(0-2.5A) |
||||
Repeatability (CV %) |
≤2% |
||||
Quality Control |
Levy Jennings quality control program at 3 levels |
||||
Bar Code |
Optional |
||||
Printer |
Multiple report formats available |
||||
Test Control Function |
New card control 3 stem available on request |
||||
Language |
English, French, Spanish, German, Russian, etc. |
||||
System |
Windows XP or Vista ; Windows 7 |
||||
Power Supply |
220V / 50Hz or 110V / 60Hz (optional) |
||||
Dimension |
100*85*70cm |
85*72*53cm |
85*72*53cm |
65*53*52cm |
|
Wight |
137Kg |
90Kg |
85Kg |
45Kg |